Redundant automation for sliding doors to be installed on emergency exit
REV-S
REV-S single-leaf, with a load capacity up to 200 kg per leaf, and a clear opening width of 700 - 3000 mm
Overview
An operator designed to be installed in escape routes, extremely safe, reliable and easy to install thanks to its innovative technical solutions. The redundant system ensures that, should any component of the main automation system fail, the secondary system takes over and performs the emergency opening of the door.
The operator is equipped with a double brushless motor housed in a single casing; this provides greater reliability than a system with two separate motors.
The electronic control unit, extremely compact and featuring highly reliable, next-generation components, is equipped with a switching power supply, with a double independent power circuit for motor piloting and with two constantly synchronised microprocessors for input and output management.
The system uses a monitored lead battery to ensure that the door opens within 5 seconds in case of failure.
The “redundant” system ensures that, should any part of the main automation system fail, the secondary system will take over to perform emergency opening of the automatic door, while the incorporated emergency battery ensures that the door will open in emergency mode within 5 seconds, in the event of a malfunction
Technical Specifications:
- Leaves: 1 leaf
- Clear Passage Width: 700 ÷ 3000 mm
- Max Load Capacity: 200 kg per leaf
- Automation Size (HxTxL): 120 x 150 mm x L (max 6500 m)
- Power Supply: 230 Vac, 50-60 Hz
- Opening Speed (Max): 0.7 m/sec
- Closing Speed (Max): 0.6 m/sec
- Operating Temperature Range: -15°C to +50°C
- Protection Rating: IP22
- Max Power Consumption: 100 W
- Stand-by Power Consumption: 6 W
- Motor Type: 24 Vdc Brushless with Encoder
- Use Frequency: Continuous 100% use
- Tested Opening Cycles: 1,000,000 cycles (approx. 4,000 cycles/day)
- Safety Test: Safety sensors monitored before each opening and closing
- Emergency Battery: Incorporated; ensures door opening during power failure or fault
- Fault Safety System: Compliant with performance level “d” of EN 13849-1